Monday, March 28, 2011

Lab 80 - RIPv2 Timers

Prerequisites: CCNP level skills.

Topology
Pic. 1 - Topology Diagram.
Icons designed by: Andrzej Szoblik - http://www.newo.pl

Task 1
Configure timers in RIP domain as follows:
  • Advertisements: 15 seconds
  • Invalid: 90 seconds
  • Holddown: 90 seconds
  • Flush: 120 seconds
Ensure that RIP convergence between R1 and R3 uses default timers.

Lab Solution

Task 1
Configure timers in RIP domain as follows:
  • Advertisements: 15 seconds
  • Invalid: 90 seconds
  • Holddown: 90 seconds
  • Flush: 120 seconds
Ensure that RIP convergence between R1 and R3 uses default timers.

On ALL Routers:
router rip
 timers basic 15 90 90 120
!

R1 Configuration:
!
interface serial0/1
 ip rip advertise 30
!

R3 Configuration:
!
interface serial0/1
 ip rip advertise 30
!